Question1: Your customer has the storage configuration for a FlexPod solution shown below.
- FAS8040 HA-pair
- Disk stack one-4x DS4243 disk shelves (2TB SATA disk drives)
- Disk stack two- 2x DS 2246 disk shelves (1.2TB disk drives)
- There are no unused SAS ports on either controller
- There are no expansion slots available on either controller
The customer wants to attach a single DS2246 disk shelf with 800 GB SSD drives.
In this scenario, what are two ways to connect the new shelf for optimal performance? (Choose two).

Question2: Exhibit:

You have a NetApp cluster and have just performed a storage failover giveback command from the CLI.
Referring to the exhibit, what is the status of the storage failover process?

Question3: An administrator has a FlexPod solution using VMware vSphere 6.0. The ESXi hosts use iSCSI for storage connectivity, and all paths have been configured and connected between the NetApp cluster and the ESXi hosts.
Virtual Storage Console has been installed and ESXi host-recommended settings have been applied to all hosts. The active LUN path for one of the iSCSI datastores experiences a connectivity failure and the LUN switches to a new active path.
In this scenario, which event would trigger the ESXi host to switch the active LUN path again?

Question4: Which set of commands maps VLAN 100 to VSAN 100?

Question5: While working on a performance related issue on your FlexPod solution, you notice an unequal distribution of traffic over the physical interfaces of a four port vPC between two Nexus 5000 switches. You would prefer a more even traffic distribution.
Which command would you use to accomplish this task?

Question6: An administrator is deploying a FlexPod solution for use with VMware vSphere 6.0. The storage environment consists of a two-node AFF8040 cluster running clustered Data ONTAP 8.3 with a single DS2246 disk shelf fully populated with 800 GB SSD drives.
The system is configured to use Advanced Drive Partitioning (ADP). The administrator wants to ensure that each node is configured with the same amount of recourses while also using hot spares for resiliency.
In this scenario, how many total disk partitions will each node have available for the data aggregate?

Question7: Which of the following tools is designed to inventory existing VMware vSphere, Linux, and Microsoft Windows Server versions in a customer environment?

Question8: When configuring a FlexPod environment for iSCSI boot with Cisco UCS, which item should be preconfigured?

Question9: After deploying a FlexPod solution, which tool would you use to validate a successful installation?

Question10: Your company is looking for a small remote office infrastructure to deploy to your 30 remote sites. You are asked to write deployment procedures for each site. Your goal is to have each site deployed in less than a day.
Which tool will help you accomplish your goal?

Question11: What management solution can provision all three components of a FlexPod (NetApp storage, Cisco UCS compute and Cisco Nexus network)?

Question12: What aggregate containing the root volume is created during the Clustered Data ONTAP setup process?

Question13: The storage administrator created an export policy for a volume on a NetApp cluster.
The export policy contains a single export rule with the parameters shown below.
- protocol nfs - rorule any
- clientmatch 10.1.16.0/255.255.255.0 - rwrule any
Two hosts attempt to access the volume using the NFS protocol shown below.
- HostA with IP address 10.1.17.37 sends an access request using the NFSv3 protocol
- HostB with IP address 10.1.16.24 sends an access request using the NFSv4 protocol
Which statement about this scenario is true?

Question14: There are 2 chassis tied to a pair of Fabric Interconnects.
First chassis, chassis-1, has 1 link between single IOM and Fabric Module. Second chassis, chassis-4, has 4 links between single IOM and Fabric Module. Chassis discovery policy is set for 2 links.
Which statement is true?

Question15: You are asked to increase read performance for a single aggregate; however, there are no PCI-e slots available in the NetApp cluster nodes.
In this scenario, which feature meets these requirements?

Question16: Which two are the expected outputs of network interface show? (Choose two.)

Question17: Which feature allows Cisco Nexus 7000 Series switches to be virtualized at the device level?

Question18: You currently have a FlexPod Datacenter solution, and you are merging with another company. That company's environment currently has a mix of different Cisco servers. You want to add as many of those servers to your FlexPod solution as possible.
In this scenario, which two Cisco servers are supported in a FlexPod environment? (Choose two.)

Question19: Exhibit:

Which Cisco switch is shown in the exhibit?

Question20: Which service may be used to manage users and groups in a vSphere environment?

Question21: Which endpoint's firmware can be directly upgraded (without the use of a Service Profile) using UCS Manager?

Question22: You are installing a FlexPod Express solution with a NetApp AFF A250 at a customer's remote site.
In this scenario, which two devices are required to provide an NFS v3 datastore? (Choose two.)

Question23: Exhibit:

You just finished cabling a UCS 5108 chassis to the Fabric Interconnects.
Which diagram in the exhibit is cabled correctly according to the CVD guidelines?

Question24: An administrator is configuring a Flexpod Datacenter solution. The UCS service profiles will use FCoE connectivity to the NetApp cluster.
Which pool is needed to configure the vHBA templates?

Question25: Exhibit:

You have a FlexPod solution with vSphere ESXi. When you click the icons shown in the exhibit, you do not see any network connectivity details.
Which Cisco UCS policy type should you create to enable visibility of these details?

Question26: Which type of pools do you need to create vHBA templates?

Question27: You want to run the FlexPod execution profile in NetApp Config Advisor.
Which three login credentials are required to perform this task? (Choose three.)

Question28: Refer to the exhibit.

When configuring a Cisco UCS B-Series server to support boot from SAN in a FlexPod deployment, which statement is correct?

Question29: Your UCS environment has recently been upgraded to include UCS B-Series Servers, UCS C-Series Servers, a UCS mini, and a fourth UCS domain. With these new changes, you need a management tool to help you manage the entire environment from a single location.
In this scenario, which tool would you use?

Question30: You are asked to install the Virtual Supervisor Module (VSM) software on a Nexus 1000v switch.
Which two sources would you use to install this software? (Choose two.)

Question31: What determines the size of the .vswap file for a VMware VM?

Question32: When connecting the Nexus 1110-X to the Nexus switch, what Spanning Tree port type is used?

Question33: Your company has acquired a new NetApp EF600 storage array with a 25 Gbps HIC.
In this scenario, which FlexPod-supported protocol should be used to connect to this array?

Question34: Which sends support summary information to NetApp through HTTPS?

Question35: NetApp recommends that your SSL key length be?

Question36: Which server role is required to support running virtual machines on a Microsoft based hypervisor?

Question37: Which management tool is used to configure and monitor centralized policies for multiple Cisco UCS domains?

Question38: Exhibit:

An administrator is building a FlexPod configuration with UCS 6296 Fabric Interconnect devices that support legacy Fibre Channel 9FC) connections. The administrator uses UCS Manager to configure the unified ports on the Fabric Interconnect.
Referring to the exhibit, how many ports will FC use after the configuration is completed?

Question39: Exhibit:

Referring to the exhibit, which two diagrams show the correct way to cable a new NetApp clustered Data ONTAP cluster with two nodes? (Choose two.)

Question40: An administrator has a FlexPod solution for use with a VMware vSphere 6.0 environment. The virtual environment consists of virtual machines running both Windows Server 2012 R2 and Windows Server 2008.
The administrator determines that the Windows Server 2008 virtual machine VMDKs are misaligned. The problem needs to be solved without incurring downtime on the virtual machines.
Which tool enables the administrator to solve the problem without virtual machine downtime?

Question41: You have a two-node NetApp clustered Data ONTAP storage system, a Cisco UCS system with two Fabric Interconnects, and a dual-fabric (Fabric-A and Fabric-B) Fibre Channel topology with the information shown below.
- Node 01 has one 10Gb FCoE connection to Fabric-A and one 10Gb FCoE connection to Fabric-B.
- Node 02 has one 10Gb FCoE connection to Fabric-A and one 10Gb FCoE connection to Fabric-B.
- Fabric Interconnect A has a two-port FCoE port channel to Fabric-A
- Fabric Interconnect B has a two-port FCoE port channel to Fabric-B.
- Each IOM in the Cisco UCS blade chassis has four uplinks into the Fabric Interconnects.
- A service profile running VMware ESXi has one vHBA in Fabric-A and one vHBA in Fabric-B.
How many paths should ESXi see to its FC boot LUN?

Question42: Which FlexPod management tool allows you to manage Storage Virtual Machines (SVMs) and replication relationships?

Question43: A customer uses Cisco Intersight and now wants to monitor their NetApp storage system with Intersight.
In this scenario, which three actions must be completed to accomplish this task? (Choose three.)

Question44: A customer asks you to configure QoS on a Cisco Nexus 7000 Series switch within a FlexPod solution.
Which three steps are required to accomplish this task? (Choose three.)

Question45: Exhibit:

Referring to the exhibit, what do the asterisks on the left indicate about the output of the ~show zoneset active~ command?

Question46: You have a NetApp clustered Data ONTAP storage system and vSphere 6 cluster. You discover that VMware VAAI for NFS is not showing as enabled on one of the five ESXi hosts in your vSphere cluster.
In this scenario, what must you do to enable VAAI for NFS on that ESXi host?